Family name: GBU72
-
Constituent part numbers: 3BHE055094R0002 (master control), 3BHE031197R0001 (gate driver), 3BHB030310R0001 (sensor front-end)
-
Platform integration: MACH™ HVDC control & protection system, PCS6000 medium-voltage converters, and grid-connected energy-storage inverters
-
-
Detailed content
-
Electrical Ratings
-
DC system voltage span: 80 kV – 800 kV DC
-
Rated breaking current: 25 kA (peak) cleared within < 3 ms
-
Control power: 110/220 V DC ±20 % or 24 V DC ±10 % depending on sub-module
-
Communication: IEC 61850-9-2LE over fiber optic, Profibus-DP, Modbus-TCP/RTU, CANopen
-
-
Functional Architecture
-
3BHE055094R0002 – Master Control Unit
– Dual-redundant DSP + FPGA real-time core
– Executes DCC800 protection algorithms: di/dt, dv/dt, differential current, back-up over-current (SIL3)
– Cycle time < 10 µs, fiber-optic latency < 1 µs to pole control -
3BHE031197R0001 – Gate Driver
– ±15 V, 200 A pulse capability for IGBT/IGCT valve triggering
– Propagation delay < 50 µs, jitter < 5 µs
– Salt-fog corrosion class ISO 12944 C5-M for offshore wind -
3BHB030310R0001 – Sensor Interface
– 1 MHz sampling, 16-bit resolution, Rogowski coil input
– ±50 kV/µs common-mode rejection, fibre-isolated outputs
– Built-in self-test and calibration routines
-
-
Protection & Performance Highlights
-
Hybrid breaker topology: mechanical contact for conduction loss < 0.1 %, solid-state stack for interruption
-
Fault detection latency: 2 ms from over-current onset to trip command
-
Grid support: LVRT, HVRT, zero-voltage ride-through per IEC 61400-21 & IEEE 1547-2018
-
Hot-swap modules; MTBF > 150 000 h per IEC 61709
-
-
Mechanical & Environmental
-
Enclosure protection: IP54 (standard), IP65 offshore variant
-
Operating temperature: –40 °C … +70 °C
-
Storage temperature: –50 °C … +85 °C
-
Vibration & shock: IEC 60721-3-3 class 3M6, seismic IEEE 693-2005 high level
-
Weight per complete breaker bay: ≈ 600 kg; sub-modules 0.8 – 3 kg depending on function
-
-
Application Scenarios
-
HVDC transmission: VSC-HVDC and LCC-HVDC schemes as primary DC protection breaker
-
Offshore & onshore wind: turbine nacelle or tower-base grid connection up to 15 MW per unit
-
Grid-scale battery storage: PCS6000 inverter bays performing charge/discharge control and fault isolation
-
Industrial microgrids: seamless islanding, black-start, and frequency regulation
-
Retrofit of existing medium-voltage drives and synchronous condensers for enhanced grid-code compliance
-
-
Certification & Standards
-
IEC 62271-307 HVDC circuit-breaker standard
-
IEC 61850-9-2LE sampled values & GOOSE messaging
-
CE, UL 1741-SA, DNV-GL offshore type approval
-
-
Service & Lifecycle
-
ABB Ability™ remote monitoring: breaker wear, contact erosion, capacitor health
-
24/7 global technical support, on-site commissioning, 48-hour spare-part delivery
-
Design lifetime > 20 years with scheduled maintenance intervals every 5 years
-
Discover our other products
KEBA Membrane Keypad Keyboard Switch Button for KEBA KEMRO K2 0I280/Y OI280/Y /
KEBA KEBA Wallbox MID 22 Kw p30 X Series WLAN 105.155 RFID 98.131 KeContact RFID Stec
KEBA Adept Technology Keba KeTop C50 ADP2 T2 Pendant 10m | 05215-110 | REV:A
KEBA LCD Display For KEBA SX TPU 2 16/64 3HAC023195-001 3HAC023195-001 /02 /03/04
KEBA SO24.002.0020. 0000.1 KEBA-LTI MOTION SO24.002.0020. 00.1 SERVO VERSION 4.20-08
KEBA SO24.002.0020. 0000.1 SO24.002.0020. 0000.1 VERS 4.00-04
KEBA KEBA D1629C-1 / D1629C1 (USED)
KEBA 1pcs New KEBA DI240/B #T8
KEBA KEBA EPS24V POWER SUPPLY Warranty!!!!
KEBA KEBA DI 260/A PLC MODULE